Lojer Components - DC Gearmotors

     > CONTACT US < - Lojer Components - 56 The Broadway - Thatcham - UK - RG19 3HP - Tel: 01635 865882

DC Gear-motors

Typical values at ambient temperature +20° L149
Tolerance +/- 10%
TYPE

NOMINAL
VOLTAGE

L

RATIO
TO :1

MAXIMUM
TORQUE

SPEED CURRENT

NO LOAD

AT MAX
TORQUE

NO LOAD

AT MAX
TORQUE

v mm Ncm rpm mA
L 149 4
6
12
10 4,5
6
12
36 10 1,5 255
215
255
165
120
165
<35
<30
<20
100
85
50
L 149 4
6
12
21 4,5
6
12
36 20,8 2,5 125
105
125
80
60
80
<35
<30
<20
100
85
50
L 149 4
6
12
43 4,5
6
12
41 43,3 3,8 60
52
60
40
32
40
<35
<30
<20
100
85
50
L 149 4
6
12
90 4,5
6
12
41 90,3 8 30
25
30
18
13
18
<35
<30
<20
100
85
50
L 149 4
6
12
188 4,5
6
12
46 188 14 14
12
14
9
7
9
<35
<30
<20
100
85
50
L 149 4
6
12
392 4,5
6
12
46 391,8 20 7
6
7
5
4
5
<35
<30
<20
90
75
45
Download PDF
@ Contact us

VDR interference suppression on the collector
Direction of rotation depending on polarity
Can be mounted in any position
Maximum radial shaft load: 10N
Maximum axial shaft load: 5N
Temperature range: -20°C/60°C
Approx weight: 55g

RH158 RH159 HV155 B138F B138F.4/12 BS138F BS138F.4/12 E192 P205
gear-motors with Hall-effect encoder
LE149 BSE138F HLE149/HVE155 RHE158/RHE159
gear-motors with two-phase Hall-effect 90° encoder
L149-2S BS138F-2S HL149-2S/HV155-2S RH158-2S/RH159-2S E192-2S P205-2S